OpenFlows WaterCAD 2024 v24.00.00.26

Description

OpenFlows WaterCAD 2024 v24.00.00.26

WaterGEMS and WaterCAD 2024 (version 24.00.00.XX) introduces improvements and features to help you be more successful. Note: A new version (version 24.00.00.26) has been released. You will need this version to integrate with ArcGIS Pro 3.3.

Table of Contents

  • Query-based Active Topology
  • Selection Set Groups
  • ArcGIS Pro Usability Improvements
    • Layer and style symbol improvements
      • Custom symbols for element types
      • Symbols automatically applied to layers
    • Streamlined layer symbology (color coding) workflow
    • Layers automatically assigned to groups
  • ModelBuilder support for ArcGIS Online features
  • "Find Pipes Referenced by Isolation Valve" query
  • Graph Tips feature
  • Access Database Engine 2016 installation
  • Installation file path update
  • Supported Operating Systems and Platforms
  • Model Compatibility
  • Stability enhancements and fixes to reported issues

Query-based Active Topology

With query-based active topology, you can now set active topology for a system based on a query. To facilitate this, a new Year Retired property has been included for pipes and different nodes, like tanks and pumps.

 

To use this feature, go to the Home or Tools tab and select Active Topology. There is an item called Edit Active Topology Mode, where you can choose to select active topology from the drawing or based on a query. You can also set this Active Topology Mode in the Active Topology alternative.

 

 

 

 

If you select to choose active topology based on a query, you can then edit your queries through the item in the Ribbon interface or in the alternative. Clicking the Edit Queries will open the Query manager. Click the New button to add an element type. You can select Pipe or Customer Meters. Once the element is selected, click the Query Builder button to create the query.

 

 

 

Suppose you want to create a query based on year a conduit was installed. After choosing Pipe as the element type for the query, click Query Builder. You will see a list of properties to choose from. Select "Year Installed," then the operator, then enter a value. You click the Unique Valves to see a list of values from the properties field.

 

 

 

Click Okay, and the query will be included in the Queries manager. To apply this to the model, click the Apply button. The number of elements will be listed.

 

 

 

To apply this query to Active Topology, go to the Home or Tools tab and select Active Topology > Apply Queries. You can also do this operation through the Active Topology alternative.