- Size:1DVD
- Language:english
- Platform:WIN32&WIN64
- Freshtime:2014-07-03
- Search:GibbsCAM 2014 GibbsCAM tutorials
Description
The following is a collection of improvements and fixes to the GibbsCAM product. The improvements and fixes date from GibbsCAM v10.6.0. Please note that this is not a complete list of all fixes, but a list of items you may have some interest in. The list contains a bug numbered followed by an ID number that has been given to a client by Technical Support when a bug is reported followed by a description of the bug or feature. This code is included so our clients can easily find their bugs. This list is sortable, clicking on a header will sort the contents by that category.
32170 VCM-81963-321 10.7.11 Update: Implemented a change so that the "Recovery Tool" would no longer show up on the main Windows Start menu.
34541 RGU-35169-131, NLT-48939-437, FWC-47347-583 10.7.11 Fix: Resolved an issue that prevented spring passes on the pocket floor when the ramp down parameter was enabled.
36009 10.7.11 Fix: Resolved an issue in the BottomUpHitFlats Plug-In that caused incorrect cutting when multiple flats are defined at the same depth.
36015 10.7.11 Update: Implemented a "GOHOME" command at tool change in the Mori-AptCL output.
36080 10.7.11 Update: Implemented a new parameter so that macro's can access the included angle for round lathe inserts.
36384 ILA-36415-723, RFS-31726-834, HDQ-88884-553 10.7.11 Fix: Resolved an issue that was causing extracted edges to deviate more than the specified tolerance.
36467 10.7.11 Post: Implemented a post command that will get the axis vectors.
34875 EBB-89283-252 10.7.10 Fix: Resolved an issue that prevented GibbsCAM from importing a specific Unigraphics part file.
35881 DCI-53389-558 10.7.10 Fix: Resolved an issue in Virtual Gibbs that caused overlapping text in the Operation Summary List.
35965 NSB-32858-689 10.7.10 Fix: Resolved an issue that caused GibbsCAM to shut down after right clicking on empty operation tiles.
35841 10.7.9 Update: Implemented the Parasolid v26.01.211 library into GibbsCAM v10.7.x.
34649 10.7.8 Update: Validation and certification of full and proper compatibility between GibbsCAM and Inventor 2015.
34938 IRN-58758-262 10.7.8 Fix: Resolved an issue that caused GibbsCAM to shut down when selecting the Profiler.
35569 CVM-79389-999 10.7.8 Fix: Resolved an issue that prevented a Mill Contour operation from machining the complete part shape.
35595 LCY-64591-185 10.7.8 Fix: Resolved an issue that caused GibbsCAM to shut down after redoing operations and running FlashCPR.
35679 10.7.8 Fix: Resolved an issue that caused GibbsCAM to shut down while attempting to import a "Step" file.
35690 UGH-62131-914 10.7.8 Fix: Resolved an issue that prevented a Mill Contour process from retaining the "Op Comment" in the Operation Data dialog.
34024 DJD-91924-237 10.7.7 Fix: Resolved an issue that caused a Milling Roughing operation to produce unnecessary motion when the "Use Stock" function was enabled.
34325 BKL-83416-798 10.7.7 Fix: Resolved an issue that caused a Milling Roughing operation to produce a rapid move to the face of the material.
34352 HFV-76178-256 10.7.7 Fix: Resolved an issue that caused a Milling operation to cancel cutter compensation on a retract move.
34753 ZDH-67188-448 10.7.7 Fix: Resolved an issue that caused a Mill Roughing operation to gouge the part.
34830 GVM-87647-181 10.7.7 Fix: Resolved an issue that prevented a Mill Roughing operation from producing toolpath when a fixture was defined.
35022 QDZ-18838-463 10.7.7 Fix: Resolved an issue that prevented a Mill Contour operation from generating toolpath due to small gaps.
35026 10.7.7 Fix: Resolved an issue that prevented a particular Mill Roughing operation from generating all of the required ramp plunge moves.
35501 10.7.7 Fix: Resolved an issue that prevented particular solid modelling operations from retaining their original identification name.
34945 10.7.6 Update: Implemented a new logo to the GibbsCAM Help About dialog.
34952 CVR-82596-187 10.7.5 Fix: Resolved an issue that was causing GibbsCAM to periodically freeze up for a few seconds.
34432 UDF-82743-425 10.7.4 Fix: Resolved an issue that prevented the VoluMill function "MinToolpath Rad" from retaining the previous used value.
34758 10.7.4 Update: Implemented a standalone version of the "GibbsCAM Add-In for Inventor" designed for saving Inventor parts, on systems that GibbsCAM doesn't exist.
34794 SEE-15329-646 10.7.4 Fix: Resolved an issue in the 5-axis module that caused more gouge check features to be applied then what was actually selected.
34826 WDU-78949-415 10.7.4 Fix: Resolved an issue that caused a distorted image while rendering in FlashCPR and using the POV Lock function.
34808 10.7.3 Fix: Resolved an issue in foreign languages that caused some 5-axis dialog fonts to display incorrectly.
26240 XRW-15347-738 10.7.2 Fix: Resolved a documentation issue that caused confusion regarding the folder location for custom reporter templates.
26594 TZD-34471-164 10.7.2 Fix: Resolved an incorrect documentation issue regarding the "OpCRCOffset" command.
32765 LET-97648-847 10.7.2 Update: Implemented documentation describing how to customize the GibbsCAM Reporters.
34430 UDF-82743-425 10.7.2 Fix: Resolved an issue in the VoluMill dialog that prevented the "Exit Clearance" field from highlighting when using the tab key.
34470 TKA-35946-752 10.7.2 Fix: Resolved an issue in 4-axis Wire EDM that prevented correct synchronization between top and bottom shapes.