GibbsCAM.2014.10.7.11.0

Description

The following is a collection of improvements and fixes to the GibbsCAM product. The improvements and fixes date from GibbsCAM v10.6.0. Please note that this is not a complete list of all fixes, but a list of items you may have some interest in. The list contains a bug numbered followed by an ID number that has been given to a client by Technical Support when a bug is reported followed by a description of the bug or feature. This code is included so our clients can easily find their bugs. This list is sortable, clicking on a header will sort the contents by that category. 32170 VCM-81963-321 10.7.11 Update: Implemented a change so that the "Recovery Tool" would no longer show up on the main Windows Start menu. 34541 RGU-35169-131, NLT-48939-437, FWC-47347-583 10.7.11 Fix: Resolved an issue that prevented spring passes on the pocket floor when the ramp down parameter was enabled. 36009 10.7.11 Fix: Resolved an issue in the BottomUpHitFlats Plug-In that caused incorrect cutting when multiple flats are defined at the same depth. 36015 10.7.11 Update: Implemented a "GOHOME" command at tool change in the Mori-AptCL output. 36080 10.7.11 Update: Implemented a new parameter so that macro's can access the included angle for round lathe inserts. 36384 ILA-36415-723, RFS-31726-834, HDQ-88884-553 10.7.11 Fix: Resolved an issue that was causing extracted edges to deviate more than the specified tolerance. 36467 10.7.11 Post: Implemented a post command that will get the axis vectors. 34875 EBB-89283-252 10.7.10 Fix: Resolved an issue that prevented GibbsCAM from importing a specific Unigraphics part file. 35881 DCI-53389-558 10.7.10 Fix: Resolved an issue in Virtual Gibbs that caused overlapping text in the Operation Summary List. 35965 NSB-32858-689 10.7.10 Fix: Resolved an issue that caused GibbsCAM to shut down after right clicking on empty operation tiles. 35841 10.7.9 Update: Implemented the Parasolid v26.01.211 library into GibbsCAM v10.7.x. 34649 10.7.8 Update: Validation and certification of full and proper compatibility between GibbsCAM and Inventor 2015. 34938 IRN-58758-262 10.7.8 Fix: Resolved an issue that caused GibbsCAM to shut down when selecting the Profiler. 35569 CVM-79389-999 10.7.8 Fix: Resolved an issue that prevented a Mill Contour operation from machining the complete part shape. 35595 LCY-64591-185 10.7.8 Fix: Resolved an issue that caused GibbsCAM to shut down after redoing operations and running FlashCPR. 35679 10.7.8 Fix: Resolved an issue that caused GibbsCAM to shut down while attempting to import a "Step" file. 35690 UGH-62131-914 10.7.8 Fix: Resolved an issue that prevented a Mill Contour process from retaining the "Op Comment" in the Operation Data dialog. 34024 DJD-91924-237 10.7.7 Fix: Resolved an issue that caused a Milling Roughing operation to produce unnecessary motion when the "Use Stock" function was enabled. 34325 BKL-83416-798 10.7.7 Fix: Resolved an issue that caused a Milling Roughing operation to produce a rapid move to the face of the material. 34352 HFV-76178-256 10.7.7 Fix: Resolved an issue that caused a Milling operation to cancel cutter compensation on a retract move. 34753 ZDH-67188-448 10.7.7 Fix: Resolved an issue that caused a Mill Roughing operation to gouge the part. 34830 GVM-87647-181 10.7.7 Fix: Resolved an issue that prevented a Mill Roughing operation from producing toolpath when a fixture was defined. 35022 QDZ-18838-463 10.7.7 Fix: Resolved an issue that prevented a Mill Contour operation from generating toolpath due to small gaps. 35026 10.7.7 Fix: Resolved an issue that prevented a particular Mill Roughing operation from generating all of the required ramp plunge moves. 35501 10.7.7 Fix: Resolved an issue that prevented particular solid modelling operations from retaining their original identification name. 34945 10.7.6 Update: Implemented a new logo to the GibbsCAM Help About dialog. 34952 CVR-82596-187 10.7.5 Fix: Resolved an issue that was causing GibbsCAM to periodically freeze up for a few seconds. 34432 UDF-82743-425 10.7.4 Fix: Resolved an issue that prevented the VoluMill function "MinToolpath Rad" from retaining the previous used value. 34758 10.7.4 Update: Implemented a standalone version of the "GibbsCAM Add-In for Inventor" designed for saving Inventor parts, on systems that GibbsCAM doesn't exist. 34794 SEE-15329-646 10.7.4 Fix: Resolved an issue in the 5-axis module that caused more gouge check features to be applied then what was actually selected. 34826 WDU-78949-415 10.7.4 Fix: Resolved an issue that caused a distorted image while rendering in FlashCPR and using the POV Lock function. 34808 10.7.3 Fix: Resolved an issue in foreign languages that caused some 5-axis dialog fonts to display incorrectly. 26240 XRW-15347-738 10.7.2 Fix: Resolved a documentation issue that caused confusion regarding the folder location for custom reporter templates. 26594 TZD-34471-164 10.7.2 Fix: Resolved an incorrect documentation issue regarding the "OpCRCOffset" command. 32765 LET-97648-847 10.7.2 Update: Implemented documentation describing how to customize the GibbsCAM Reporters. 34430 UDF-82743-425 10.7.2 Fix: Resolved an issue in the VoluMill dialog that prevented the "Exit Clearance" field from highlighting when using the tab key. 34470 TKA-35946-752 10.7.2 Fix: Resolved an issue in 4-axis Wire EDM that prevented correct synchronization between top and bottom shapes.

Download

Related recommendations