- Size:1CD
- Language:english
- Platform:Win7/WIN10
- Freshtime:2026-05-13
- Search:Carrier SDL 6.4 crack Carrier SDL 6.4 download Carrier SDL 6.4 training
Description
Carrier SDL 6.4: System-Based HVAC Load Calculation Software
SDL 6.4 (System Design Load) is Carrier's latest version of the professional HVAC load calculation program, released as part of the eDesign Suite alongside HAP 6.4 . It uses ASHRAE Heat Balance methodology and system-based design principles to accurately size commercial building HVAC systems .
Key Features
System-Based Load Calculation
-
ASHRAE Heat Balance Method: Calculates design cooling and heating loads using industry-standard algorithms for peak load analysis
-
System-Specific Sizing: Tailors calculations for individual system types—Single Zone CAV, VAV, Fan Powered Mixing Box, VRF, induction, fan coils, PTACs, water-source/ground-source heat pumps, chilled beams
-
Complete Psychrometrics: Altitude-adjusted analysis with dehumidification controls, economizers, and heat reclaim
Building & Component Modeling
-
3D Building Modeling: Same as HAP v6; supports sloped roofs, skylights, external shading, and 16 principal exposures
-
Construction Libraries: Pre-defined wall, roof, window, and interior shading constructions with custom entry options
-
Scheduling: Equipment operation from 1-24 hours; hourly scheduling for lights, occupancy, appliances, and thermostats
Advanced Analysis
-
Morning Pulldown: Calculates recovery loads after nighttime setbacks
-
Return Plenum & Duct Leakage: Models realistic system losses
-
Thermostat Throttling: Accounts for control band effects on zone loads
-
Outdoor Ventilation: ASHRAE Standards 62.1 (2004–2019 editions)
Technical Specifications
| Feature | Details |
|---|---|
| Version | 6.4 |
| Developer | Carrier |
| Methodology | ASHRAE Heat Balance, ASHRAE clear sky solar algorithms |
| Weather Data | 7,000+ cities worldwide |
| Output | Text files for word processors/spreadsheets; graphical outputs |
| Integration | Import/export gbXML |
Applications
-
Commercial building HVAC load calculation (offices, hospitals, hotels, retail)
-
System sizing for air handlers, cooling/heating coils, fans, and central plants
-
Ventilation compliance per ASHRAE 62.1
-
Energy-efficient design alternatives comparison
Rank Math SEO Suggestions
Focus Keywords:
Carrier SDL 6.4, HVAC load calculation software, System Design Load, ASHRAE Heat Balance, commercial building load calculation
SEO Title:
Carrier SDL 6.4 | System-Based HVAC Load Calculation Software
Meta Description:
Carrier SDL 6.4 calculates commercial building cooling/heating loads using ASHRAE Heat Balance. System-based design for VAV, VRF, fan coils, and more. Part of Carrier eDesign Suite.
Tags:
Carrier SDL 6.4, System Design Load, HVAC load calculation, ASHRAE Heat Balance, commercial HVAC, VAV sizing, VRF load calculation, cooling load, heating load, psychrometric analysis, ventilation ASHRAE 62.1, gbXML import, 3D building modeling, Carrier eDesign Suite, system-based design, fan coil sizing, water-source heat pump, ground-source heat pump, chilled beam