Siemens.NX.v10.0.2.Update.Only

Description

Siemens.NX.v10.0.2.Update.Only NX VERSION 10.0.2.6 Windows (64 Bit) Issued: July 2015 Files on this media are intended for use on the 64 Bit Windows 7 and Windows 8 platform only. The software will not work on 32 bit machines. ____________________________________________________________________________ BACKUP SUGGESTIONS: The update does not provide an automatic rollback mechanism to 'undo' the update. Installers that anticipate a need to revert to the previously installed version must make a backup copy of the entire %UGII_BASE_DIR% folder tree before doing the update. If it is necessary to go back to the old version, simply replace the updated %UGII_BASE_DIR% folder with the backup copy. ____________________________________________________________________________ UPDATE INSTRUCTIONS: This media contains Maintenance Release files provided as replacements for previously installed NX 10.0 products. The Base release for this maintenance release is a prerequisite to installing this update. e.g. Version XX.Y must be installed before updating to Version XX.Y.Z Several methods are provided to perform the update: 1. Autoplay the DVD then select 'Install NX Update'. 2. Or, run the DVD 'launch.exe' program then select 'Install NX Update'. 3. Or, change dir to the ugs_updateXXXX folder then run 'run_ugsupdate.exe'. The above methods will all run 'run_ugsupdate.exe'. It reads the correct %UGII_BASE_DIR% from the Registry and apply the update to the folder. 4. OR, you may follow the instructions below to run ugs_update.bat directly. Change directory to the 'ugs_updateXXXX' folder, check that UGII_BASE_DIR is set to the installed NX 10.0 folder, then execute the 'ugs_update.bat' script. e.g. cd ugs_updateXXXX ugs_update.bat /v The use of UNC pathnames (e.g. \serverpath) is supported by both ugs_update.bat and run_ugsupdate.exe. The script supports a "/v" switch to turn on verbose messages while doing the file updates. The default operation of the script is non-verbose. The script supports a "/d" switch. This will turn off the script confirmation prompts. Useful for running the update in a batch job. The script also supports a "/p" switch. This will turn off the initial confirmation prompt but it will display the final 'done' prompt. This is useful for running the update in a batch job where a final prompt is desired. NOTE: Before running the ugs_update script, please make sure that the environment variable %UGII_BASE_DIR% is set to the base directory of the NX 10 release. e.g: set UGII_BASE_DIR="C:Program FilesSiemensNX 10.0" Or set the variable to the appropriate installed folder on your system. SILENT UPDATES: Advanced users may use standard DOS output redirection to install the update silently with no screen displays, except on errors. For example, to turn off all output: e.g: ugs_update /d >NUL 2>&1 - or - run_ugsupdate.exe >NUL 2>&1 Caution: you MUST the change "switches" settings in run_ugsupdate.ini to "/d" To redirect the output to a log file. (Recommended) e.g: ugs_update /d >c:tempupdate_log.txt 2>&1 - or - run_ugsupdate.exe >c:tempupdate_log.txt 2>&1 _____________________________________________________________________________ WINDOWS 64: The software on this media can only be used on 64 bit hardware running either Windows 7 or Windows 8 64 bit operating system. The software will not work on 32 bit machines.

Download

Related recommendations